accueil

CANBERRA - Boiler Room Plan

CANBERRA   -    Boiler Room Plan
Précedente Suivante
Drawing from
The Shipbuider and Marine Engine builder
CANBERRA Souvenir number June 1961

The boilers were located aft the engine rooms (see GA Plan) on a flat. The steam was superheated at a temperature of 950 deg. F (510 C) . Each of the main boilers had a normal evaporation of 175000 lb (~ 79400 kg) per hour and a maximum evaporation of 260000 lb (~118000 kg) per hour. The steam pressure was 750 lb per sq. inch (5.2 MPa) at a temperatture of 960 deg F 515.5 C) with a feed temperature of 240 deg F (115.5 C) . The auxiliary boiler was feeding steam at the same pressure but with a normal evaporation of 40000lb (18150 kg) per hour and a maximum evaporation of 50000 lb (22700 kg) per hour.

Données photo

Macro-catégorie
Catégorie
Album
Publiée par
Enregistré Mario_from_Genoa
Date
June 1961
Lieu
Belfast
Téléchargée le
25/12/2012
Dimension
2180 x 3084
visites
1258
Partager sur
Whatsapp   Telegram   Facebook

Fiche technique

Il n'y a aucune fiche technique sur cette photo
Numéro IMO
5059953
Type de navire
Passenger Cargo Ship
Année/chantier de constr.
Harland & Wolff Belfast (UK) 1961
Armateur
P&O -Orient Lines
Ship manager
P&O -Orient Lines

Commentaires sur la photo

Vous devez être enregistré pour voir les commentaires